Hemodynamic monitoring in the Critically Ill Patient
Abstract
Caring for the critically ill patient requires management of the cardiovascular system and balance of the internal environment. Hemodynamic monitoring is therefore necessary. With the objective of describing the physiological basis of hemodynamic follow-up and means for its determination, a search for information was carried out in the –Scopus, SciELO, PubMed, LILACS, AmeliCA, and Redib– databases. Hemodynamic monitoring allows determining when fluid administration is required and its therapeutic response by analyzing the Frank Starling curve. It requires the determination of static and dynamic parameters that analyze cardiac output and pulse pressure. These parameters are measured by invasive, minimally invasive and noninvasive methods. Pulse pressure and stroke volume variability are useful new variables in the process. Echocardiographic study of the inferior vena cava plays an important role in the hemodynamic follow-up.
Downloads
References
1. Ochagavía A, Baigorri F. Introducción de la serie «Puesta al día»: Monitorización hemodinámica en el paciente crítico. Med Intensiva. 2011;35(8):497-8. DOI: https://doi.org/10.1016/j.medin.2010.10.004
2. Magder S. Volume and its relationship to cardiac output and venous return. Crit Care [Internet]. 2016 [citado 10 Jun 2020];20(1):271. Disponible en: https://doi.org/10.1186/s13054-016-1438-7
3. Martos-Benítez FD, Guzmán-Breff BI. Expansión del volumen y variación en los parámetros hemodinámicos. Emergencias. 2018;30(3):177-81.
4. Tatara T. Context-sensitive fluid therapy in critical illness. J Intensive Care [Internet]. 2016 [citado 11 Jun 2020];4:20. Disponible en: https://doi.org/10.1186/s40560-016-0150-7
5. Cárdenas A, Roca J. Tratado de Medicina Intensiva. 1ª ed. Barcelona: Elsevier; 2017. p. 191.
6. Williams RR, Wray RB, Tsagaris TJ, Kuida H. Computer estimation of stroke volume from aortic pulse contour in dogs and humans. Cardiology. 1974;59(6):350-66. DOI: https://doi.org/10.1159/000169694
7. Reuter DA, Felbinger TW, Schmidt C, Kilger E, Goedje O, Lamm P, et al. Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery. Intensive Care Med. 2002;28(4):392-8. DOI: https://doi.org/10.1007/s00134-002-1211-z
8. Monge MI, Jian Z, Settels JJ, Hunley C, Cecconi M, Hatib F, et al. Determinants of left ventricular ejection fraction and a novel method to improve its assessment of myocardial contractility. Ann Intensive Care [Internet]. 2019 [citado 15 Jun 2020];9(1):48.Disponible en: https://doi.org/10.1186/s13613-019-0526-7
9. Ochoa Solana AL. Monitorización hemodinámica en cuidado intensivo. Acta Colomb Cuid Intensivo. 2015;15(2):109-18. DOI: http://dx.doi.org/10.1016/j.acci.2015.02.004
10. Pérez-Calatayud AA, Linarte-Basilio ME, Díaz de León M, Carrillo R, Briones-Garduño JC. Monitoreo hemodinámico no invasivo y mínimamente invasivo en la paciente obstétrica grave. Med Crít. 2017;31(5):275-84.
11. Dalmau R. Consideraciones sobre la reserva de precarga en la ventilación pulmonar selectiva. Rev Esp Anestesiol Reanim [Internet]. 2020 [citado 15 Jun 2020];67(2):114-5. Disponible en: https://doi.org/10.1016/j.redar.2019.05.002
12. Takala J. Volume responsive, but does the patient need volume? Intensive Care Med. 2016;42(9):1461-3. DOI: https://doi.org/10.1007/s00134-015-4172-8
13. Dalmau R. Hemodinámica funcional: ¿Qué significa «ser respondedor»? Rev Chil Anest. 2018;47(3):176-88. DOI: https://doi.org/10.25237/revchilanestv47n03.04
14. Domínguez MF, Semanate NM, Domínguez ND, Semanate SD. Monitorización hemodinámica mínimamente invasiva en el paciente crítico. Una revisión de la literatura. Enferm Inv [Internet]. 2018 [citado 27 Jun 2020];3(Supl 1):34-9. Disponible en: https://revistas.uta.edu.ec/erevista/index.php/enfi/article/view/736/711
15. Swan HJ, Ganz W, Forrester J, Marcus H, Diamond G, Chonette D. Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. N Engl J Med. 1970;283(9):447-51. DOI: https://doi.org/10.1056/nejm197008272830902
16. Benito-Saz P, Garrido A, Quintana-Villamandos B, Barrio JM, Fernandez-Quero L, Hortal J. Perforación de la pared del ventrículo izquierdo por catéter de arteria pulmonar Swan-Ganz. A propósito de un caso. Rev Esp Anestesiol Reanim [Internet]. 2019 [citado 28 Jun 2020];66(10):528-32. Disponible en: https://doi.org/10.1016/j.redare.2019.06.006
17. Joseph C, Garrubba M, Smith JA, Melder A. Does the Use of a Pulmonary Artery Catheter Make a Difference During or After Cardiac Surgery? Heart Lung Circ. 2018;27(8):952-60. DOI: https://doi.org/10.1016/j.hlc.2018.02.004
18. Xu Y, Stout LC. Complete step section microscopic study of a Swan-Ganz catheter-related pulmonary artery rupture: a frequently lethal complication that to our knowledge has not had a comprehensive microscopic examination: case report and literature review. Cardiovasc Pathol. 2017;31:17-9. DOI: https://doi.org/10.1016/j.carpath.2017.06.011
19. Ng SC, Mythen MG. Medicina perioperatoria y función de la monitorización hemodinámica. Rev Esp Anestesiol Reanim [Internet]. 2017 [citado 30 Jun 2020];64(6):301-5. Disponible en: http://dx.doi.org/10.1016/j.redar.2016.09.009
20. Acosta J, López-Herrera D, González D, López JL. Ecocardiografía transesofágica durante el trasplante ortotópico hepático. Rev Esp Anestesiol Reanim [Internet]. 2017 [citado 28 Jun 2020];64(9):522-7. Disponible en: https://doi.org/10.1016/j.redar.2017.01.011
21. Tinoco-Solorzano A, Tácuna-Calderón AL, Rueda-Camana M, Diaz-Seminario A, Salazar-Granara A. Rotura hepática en gestante residente en gran altura y la utilidad del monitoreo hemodinámico con doppler transesofágico. Rev Chil Obstet Ginecol. 2019;84(4):314-9. DOI: http://dx.doi.org/10.4067/S0717-75262019000400314
22. Toscani L, Aya HD, Antonakaki D, Bastoni D, Watson X, Arulkumaran N, et al. What is the impact of the fluid challenge technique on diagnosis of fluid responsiveness? A systematic review and meta-analysis. Crit Care [Internet]. 2017 [citado 2 Jul 2020];21(1):207. Disponible en: https://doi.org/10.1186/s13054-017-1796-9
23. Carpio-Domínguez LE, Ledesma-Ramírez RP. ¿Es útil el Vigileo en anestesia torácica? Rev Mex Anest. 2017;40(Supl 1):S138-9.
24. Ince C, Boerma EC, Cecconi M, De Backer D, Shapiro NI, Duranteau J, et al. Second consensus on the assessment of sublingual microcirculation in critically ill patients: results from a task force of the European Society of Intensive Care Medicine. Intensive Care Med. 2018;44(3):281-99. DOI: https://doi.org/10.1007/s00134-018-5070-7
25. Mateu ML, Ferrándiz A, Gruartmoner G, Mesquida J, Sabatier C, Poveda Y, et al. Técnicas disponibles de monitorización hemodinámica: Ventajas y limitaciones. Med Intensiva. 2012;36(6):434-44. DOI: https://doi.org/10.1016/j.medin.2012.05.003
26. Berg SM, Braehler MR. The Postanesthesia Care Unit. En: Miller's Anesthesia. 9ª ed. Barcelona: Elsevier; 2020. p. 2586-613.
27. Convertino VA, Wirt MD, Glenn JF, Lein BC. The Compensatory Reserve For Early and Accurate Prediction Of Hemodynamic Compromise: A Review of the Underlying Physiology. Shock. 2016;45(6):580-90. DOI: https://doi.org/10.1097/shk.0000000000000559
28. Díaz HR, Valdés O. Ecografía clínica. Nuevas concepciones sobre una disciplina clásica en Terapia Intensiva. Rev Cub Med Int Emerg [Internet]. 2017 [citado 5 Jul 2020];16(1):65-6. Disponible en: http://www.revmie.sld.cu/index.php/mie/article/view/202/html_85
29. Valdés O, Díaz HR, Abdo A, Suárez BE. Deterioro hemodinámico en pacientes con trauma craneoencefálico. Rev Cub Med Int Emerg [Internet]. 2018 [citado 7 Jul 2020];17(Supl 2):100-9. Disponible en: http://www.revmie.sld.cu/index.php/mie/article/view/575/569
30. Valdés O. Ecografía clínica como herramienta en el diagnóstico de un paciente con disnea. Rev Cub Med Int Emerg [Internet]. 2017 [citado 7 Jul 2020];16(Supl 2):1-15. Disponible en: http://www.revmie.sld.cu/index.php/mie/article/view/300/397
31. Mercadal J, Borrat X, Guido RE, Zavala E. Ecocardiografía funcional en la unidad de reanimación como monitor hemodinámico. Med Crít. 2017;31(2):84-92.
32. Almela A, Millán J, Alonso JM, Garcia P. Monitorización hemodinámica no invasiva o mínimamente invasiva en el paciente crítico en los servicios de urgencias y emergencias. Emergencias. 2015;27(6):386-95.
33. Blancas R, Martínez-González Ó, Ballesteros D, Núñez A, Luján J, Rodríguez-Serrano D, et al. Ausencia de correlación entre la integral velocidad tiempo en el tracto de salida del ventrículo izquierdo y el índice volumen sistólico en pacientes en ventilación mecánica. Med Intensiva. 2019;43(2):73-8. DOI: https://doi.org/10.1016/j.medin.2017.11.012
34. Bañuelos-Huerta R, Jimenez B, Romero S. Medición de vena cava inferior en la reanimación con líquidos en choque séptico. Arch Med Urgen Méx. 2017;9(3):89-93.
35. Iturbide I, Santiago ML, Henain F, Golab K, Tentoni ME, Fuentes S. Evaluación ecográfica de la vena cava inferior en los pacientes hemodinámicamente inestables. Rev Argent Radiol. 2017;81(3):209-13. DOI: http://dx.doi.org/10.1016/j.rard.2016.11.008
36. Oulego I. Ecografía en el paciente hemodinámicamente inestable. Rev Esp Pediatr. 2016;72(Supl 1):62-9.
37. Josa-Laorden C, Giménez-López I, Rubio-Gracia J, Ruiz-Laiglesia F, Garcés-Horna V, Pérez-Calvo JI. Valor pronóstico de la medición del diámetro y colapso inspiratorio de la vena cava inferior en la insuficiencia cardiaca aguda. Rev Clin Esp. 2016;216(4):183-90. DOI: http://dx.doi.org/10.1016/j.rce.2015.11.012
Downloads
Published
How to Cite
Issue
Section
License
Authors who publish with this journal agree to the following terms:- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.